Blank End-stations Compared
Blank Endstation Control Panels Compared
The table below shows the features applicable to the Blank Endstation Alarm Control Panels featured on our Website.

Blank endstation control panels do not have an on-board keypad and are designed to be sited covertly. All the control panels are mains powered and should be fitted with a rechargeable back-up battery - batteries should be ordered separately.

All blank endstations must have at least one RKP connected. Where there is a choice of RKPs, the different types can be mixed. Where multiple RKPs are used it is common practice to fit one LCD RKP together with one or more LED RKPs. The LCD RKP is used for programming the system and the LED RKPs are used purely for setting/unsetting the system.

Put Mouse over the Properties below for more info...(Only works in Fiefox) Accenta Mini G4 Accenta G4 Metal Scantronic 9448EUR-95 Pyronix Sterling 10 Scantronic 9651 Series Scantronic 9751 Series Texecom Veritas R8 Texecom Veritas R8 Plus Texecom Veritas Excel MDT Avanti Polycarbonate MDT Avanti XP Metal
Style Compact Large Case Compact Large Case Large Case Large Case Large Case Large Case Large Case Compact Large Case
Construction Material Polycarbonate Steel Polycarbonate Polycarbonate Steel Steel Polycarbonate Polycarbonate Polycarbonate Polycarbonate Steel
No of Remote Keypads (RKPs) 4 Max 4 Max 2 Max (LED Only) 4 Max 4 Max (9930, 9940, or 9941 - any combination) 4 Max (9930, 9940, or 9941 - any combination) 6 Max (LED Only) 6 Max (LED or LCD) 6 Max (LED or LED) 4 Max (LED, LCD, or LCD/prox - any combination) 4 Max (LED, LCD, or LCD/prox - any combination)
No of Alarm Zones 8 8 7 8 8 8 8 8 8 8 8
Tamper Global Global Global Global Global Global Global Global or EOL Global or EOL Global or EOL Global or EOL
Personal Attack Zone Dedicated Dedicated Zone 6 can be set as a PA zone Dedicated Any zone can be set as PA Any zone can be set as PA Any zone can be set as PA Any zone can be set as PA Any zone can be set as PA Any zone can be set as PA Any zone can be set as PA
Fire Zone Any zone can be set as a FIRE zone Any zone can be set as a FIRE zone Zone 5 can be set as a FIRE zone Any zone can be set as a FIRE zone Any zone can be set as a FIRE zone Any zone can be set as a FIRE zone Any zone can be set as a FIRE zone Any zone can be set as a FIRE zone Any zone can be set as a FIRE zone Any zone can be set as a FIRE zone Any zone can be set as a FIRE zone
Entry/exit Zone 10, 20 or 30 seconds timer 10, 20 or 30 seconds timer 10, 20, 30, 45, or 60 seconds timer 0 -99 seconds timer 0 - 2 minutes timer 0 - 2 minutes timer 1 - 99 seconds timer 1 - 99 seconds timer 1 - 99 seconds timer 0 - 99 seconds timer 0 - 99 seconds timer
Pulse Count (double knock) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Chime Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Push-to-set Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes
Keyswitch Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes
Auto re-arm Yes - selectable Yes - selectable Yes - selectable Yes - selectable Yes - selectable Yes - selectable Yes - selectable Yes - selectable Yes - selectable Yes - selectable Yes - selectable
Battery Size 2.1Ah Only Up to 7.0Ah 2.1Ah Only Up to 7.0Ah Up to 7.0Ah Up to 7.0Ah Up to 7.0Ah Up to 7.0Ah Up to 7.0Ah 2.1Ah Only Up to 7.0Ah
Communicator Outputs Intruder, PA, Fire Intruder, PA, Fire Intruder, PA Intruder, PA, Fire Intruder, PA, Fire Intruder, PA, Fire None Intruder, PA, Fire Intruder, PA, Fire None None
Bell Delay Yes Yes No Yes Yes Yes No Yes Yes Yes Yes
Back

Products
Quick Find
 
Use keywords to find the product you are looking for.
Advanced Search
0 items
Manufacturers
Articles
All Articles 1
 Fitting Magnetic Contacts
All Topics
 Installation guides (1)
 Miscellaneous Articles

New Articles 1
 Fitting Magnetic Contacts
Articles RSS Feed
Find Articles



Powered by Flugelsoft